Study 1

Diagnosis and rectification of an intermittant clutch problem on a Fagor mechaniucal press equipped with an Ortlinghaus hydraulic clutch.
We succesfully identified and rectified a pressure peak of 45 milli-seconds duration that triggered an error

Study 2

Investigation into poor clutch performance together with short clutch life. Following data capture and analysis adjustments were made to the system resulting in smoother operation and much improved component lifespan.

 